BZDNM - ANAEROBIC MIXTURE

Product Identification

Product ID:ANAEROBIC MIXTURE
MSDS Date:11/01/1985
FSC:6830
NIIN:00F047884
MSDS Number: BZDNM

Responsible Party
UNION CARBIDE CORP LINDE DIV
39 OLD RIDGBURY RD
DANBURY, CT 06817-0001
US

Emergency Phone: 800-822-4357/203-794-2000

Info Phone: 203-794-6753/203-794-2000

Cage: 36346

Contractor
UNION CARBIDE CORP LINDE DIV
DANBURY, CT 06817-0001 US

Telephone: 800-822-4357; 304-744-3487

Cage: 36346

Ingredients

NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: 85%

ACGIH TLV: ASPHYXIANT


CARBON DIOXIDE *96-1*

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 5%

OSHA PEL 5000 PPM

ACGIH TLV: 9000 MG/CUM


HYDROGEN

CAS: 1333-74-0

RTECS: MW8900000

Fraction By Weight: 100%

ACGIH TLV: SIMPLE ASPHYXIANT

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: ASPHYXIANT. MODERATE
CONCENTRATIONS MAY CAUSE HEADACHE, DROWSINESS, DIZZINESS,
EXCITATION, EXCESS SALIVATION, VOMITING & UNCONSCIOUSNESS. LACK OF
OXYGEN CAN CAUSE DEATH.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: ASPHYXIANT. MODERATE CONCENTRATIONS
MAY CAUSE HEADACHE, DROWSINESS, DIZZINESS, EXCITATION, EXCESS
SALIVATION, VOMITING & UNCONSCIOUSNESS. LACK OF OXYGEN CAN CAUSE
DEATH.

First Aid

First Aid:SKIN: WASH W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR.
GIVE CPR/OXYGEN IF NEEDED. EYES: FLUSH W/WATER. OBTAIN MEDICAL
ATTENTION IN ALL CASES. NOTE TO PHYSICIAN: THERE IS NO SPECIFIC
ANTIDOTE. TRE ATMENT OF OVEREXPOSURE SHOULD BE DIRECTED AT THE
CONTROL OF SYMPTOMS & THE CLINICAL CONDITION.

Fire Fighting

Flash Point:FLAMMABLE
Lower Limits:40
Upper Limits:77
Extinguishing Media:CO2, DRY CHEMICALS, WATER SPRAY/FOG.
Fire Fighting Procedures:EVACUATE. COOL CONTAINERS FROM MAX DISTANCE
W/WATER SPRAY, DON'T EXTINGUISH FLAMES-EXPLOSIVE REIGNITION MAY
OCCUR. REMOVE IGNITION SOURCES/STOP FLOW SAFELY.(SUP
Unusual Fire/Explosion Hazard:NEARLY INVISIBLE FLAME. ESCAPING GAS
IGNITES SPO NTANEOUSLY. HYDROGEN HAS A LOW IGNITION ENERGY.
FIREBALL MAY FORM IF GAS CLOUD IGNITES AFTER RELEASE. (SUPP)

Accidental Release

Spill Release Procedures:EVACUATE AREA. USE SCBA WHERE NEEDED. REMOVE
IGNITION SOURCES W/O RISK. REDUCE GAS W/FOG/FINE WATER SPRAY. SHUT
OFF LEAK W/O RISK. MIXTURE IS AN ASPHYXIANT. VENTILATE AREA/MOVE TO
WELL VENTILATED AREA . FLAMMABLE GAS MAY SPREAD.

Handling

Handling and Storage Precautions:NEVER WORK ON PRESSURIZED SYSTEM. IF
LEAKS, CLOSE THE CYLINDER VALVE, BLOW DOWN THE SYSTEM BY VENTING TO
A SAFE PLACE, THEN REPAIR.
Other Precautions:AVOID OXIDIZING AGENTS. USE PIPING & EQUIPMENT
DESIGNED TO W/STAND PRESSURES. MAY FORM EXPLOSIVE MIXTURES W/AIR.
GROUND EQUIPMENT. USE ONLY NON-SPARKING TOOLS & EXPLOSION PROOF
EQUIPMENT. KEEP FROM HE AT & IGNITION SOURCES.

Exposure Controls

Respiratory Protection:RESPIRATORS SHALL BE ACCEPTABLE TO NIOSH/MSHA.
Ventilation:LOCAL EXHAUST, EXPLOSION PROOF SYSTEM IS ACCEPTABLE. USE IN
A CLOSED SYSTEM.
Protective Gloves:RECOMMENDED
Other Protective Equipment:METATARSAL SHOES FOR CYCLINDER HANDLING.
Supplemental Safety and Health

Chemical Properties

Vapor Pres:GAS
Vapor Density:0.905
Spec Gravity:GAS
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS GAS AT NORMAL TEMPERATURE & PRESSURE W/NO
ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
OXYGEN, OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME.

Disposal

Waste Disposal Methods:PREVENT CONTAMINATION OF SURROUNDING
ENVIRONMENT. KEEP PERSONNEL AWAY. DISCARD ANY PRODUCT RESIDUE,
DISPOSABLE CONTAINER/LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER
IAW/FEDERAL, STATE & LOCAL REGULA TIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.